Propex Heatsource blown air systems are used in many applications throughout the world, these include Motorhomes, Caravans, Cranes, Horseboxes, Mobile Workshops etc. Both 12 and 24 volt versions are available. With the correct Fitting kit they are also suitable and approved for use in Boats.
Dimensions
- W172 x H101 x D389.5mm
Features
-
Advanced micro-processor electronics
-
Self diagnostic fault finding system
-
Fast warm-up time
-
Reduces condensation in your motorhome or caravan
-
Thermostatic operation
-
Stainless steel burner and heat-exchanger with clean combustion gives maintenance free durability
-
Low power consumption
-
Compact and easy to install
-
High quality motor with ball race bearings
Warranty 1 year
Voltage 12V
Control
The HS20000 is supplied as standard with a solid state electronic thermostat which automatically switches the unit on and off to maintain the desired temperature. When the room temperature drops below the selected level, the Heatsource will automatically ignite and run until the cabin reaches the selected temperature. The thermostat is an easy to fit surface mount design and integrates with the new electronics fitted to the HS2000 and HS2800 heaters. An easy to operate panel mounted digital timer/thermostat specifically designed for Heatsource, is also available. Unlike some heaters, there is minimal electric current consumption during ignition so cycling the Heatsource on and off does not have the effect of additional battery drain.
Efficiency
With forced air combustion and the Propex two stage stainless steel heat-exchanger, the HS2000 is a clean and highly efficient way to heat your vehicle or boat. Air for combustion is taken from outside and passed into the combustion chamber having been mixed with gas during three aeration stages, it is ignited automatically and heats up the large surface area of the heat-exchanger. The Heatsource units are totally room sealed and exhaust all products of combustion externally through the neat 22mm i.d. stainless steels flue pipe. To add to the efficiency, cabin air is normally re-circulated in preference to using cold air from outside. The HS series heaters are also very efficient on electrical current consumption, the high quality motor/fan combination and innovative current reducing electronics, both of which have been improved in the latest versions, means that even the larger HS2800 draws less than 2 amps during normal operation.
Safety
Heatsource blown air heaters conform to the latest European & New Zealand standards for both the appliance and the electronics and during the rigorous testing the focus is very much on safety. The heaters also have to comply with an enhanced version of the Electro Mechanical Compatibility Directive to ensure they do not interfere with other electronics and that they are immune from interference by other electronics. The intelligent electronics are continuously monitoring the operation of the heater to make sure everything is operating correctly and safely. This includes monitoring of the flame, case temperature, combustion airflow, gas solenoid valve and voltage. Should any of these stray outside of the predetermined levels, the heater will be switched off and the red light on the thermostat will indicate a fault by flashing a certain number of times.
Installation
Supplied with a complete fitting kit to suit vehicle applications. In motohomes and caravans the unit is usually mounted under a bench seat or in a cupboard, flued downwards through the floor and out to the side of the vehicle using flexible stainless ducting. The 22mm i.d. ducts are supplied as standard in lengths of 750mm. The ends are finished with neat stainless steel end-caps which comply with EN624. The heat is ducted to one or more outlets through tough highly flexible 60mm ducting. Note: a qualified Gas Fitter is required to install this product
Specifications
-
Heating capacity 1900kW
-
Fuel Type LPG
-
Fuel Consumption (Max) 142g/h
-
Power consumption (Max) 20W
-
Heat Input 2.1kW
-
Heat Output 1.9kW
-
Current Consumption 1.4A
-
Air Throughput 1.7 cubic metres/min
-
Declaration of conformity available
-
Installation must be done by a qualified gas fitter















Reviews